Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 653
Filter
1.
Article in English | LILACS-Express | LILACS | ID: biblio-1535327

ABSTRACT

Objectives: This was a single-subject study, aimed to demonstrate different vocal demand situations that are typical for primary school and teacher's vocal demand response under two acoustical conditions, with and without voice amplification, during five working days. Methods: The long-term voice dosimetry with Vocal Holter Med (PR.O. Voice Srl) was carried out on a 49-year-old female teacher with voice disorders during daily teaching activities. A sound field amplification system (SFAS) PentaClass Runa was installed in the classroom. Voice dosimetry was provided under two different acoustical conditions: without SFAS (2 days) and with SFAS (3 days). Results: Phonation time percentage, sound pressure level (SPL), SPL SD, fundamental frequency (F0), F0 SD, cycle, and distance doses were investigated in seven communication scenarios (lessons, group/individual classes, sports lessons in the gym and schoolyard, breaks, lunch breaks, and other activities). The median scores of all voice parameters differed significantly between different vocal demand contexts. The significant statistical difference in the vocal demand response was in the communication situations with and without SFAS. In addition, the number of children, reverberation time, and ambient air relative humidity impacted voice SPL and the cycle dose. Conclusions: Lessons, sports lessons held in the gym or schoolyard, breaks, and lunch breaks were considered as high vocal demand communication situations requiring higher voice intensity and fundamental frequency, higher phonation time percentage, cycle, and distance doses. Group/individual work and other teacher activities during the day, unrelated to direct work with students, were categorized as low vocal demand communication scenarios.


Objetivos: Este fue un estudio de sujeto único, cuyo objetivo fue demostrar diferentes situaciones de demanda vocal típicas de la escuela primaria y la respuesta vocal de los docentes bajo dos condiciones acústicas, con y sin amplificación de voz, durante cinco días laborables. Métodos: Se llevó a cabo dosimetría vocal a largo plazo con Vocal Holter Med (PR.O. Voice Srl) durante las actividades diarias de enseñanza en una docente de 49 años con trastornos de la voz. Se instaló un sistema de amplificación de campo sonoro (SFAS) PentaClass Runa en el aula. La dosimetría vocal se realizó bajo dos condiciones acústicas diferentes: sin SFAS (2 días) y con SFAS (3 días). Resultados: Se investigaron el porcentaje de tiempo de fonación, el nivel de presión sonora (SPL), SPL SD, la frecuencia fundamental (F0), F0 SD, ciclos y dosis de distancia en siete escenarios de comunicación diferentes (clases, clases grupales/individuales, clases de educación física en el gimnasio y el patio de la escuela, recreos, almuerzos y otras actividades). Las puntuaciones medias de todos los parámetros vocales diferían significativamente entre los diferentes contextos de demanda vocal. La diferencia estadísticamente significativa en la respuesta a la demanda vocal se observó en las situaciones de comunicación con y sin SFAS. Además, el número de niños, el tiempo de reverberación y la humedad relativa del aire ambiente afectaron al SPL de la voz y la dosis de ciclo. Conclusiones: Las lecciones, las clases de educación física en el gimnasio o el patio de la escuela, los recreos y los almuerzos se consideraron situaciones de comunicación de alta demanda vocal, que requerían una mayor intensidad y frecuencia fundamental de la voz, un mayor porcentaje de tiempo de fonación y dosis de ciclo y distancia más altas. El trabajo grupal/individual y otras actividades del profesor durante el día no relacionadas con el trabajo directo con los estudiantes se categorizaron como escenarios de comunicación de baja demanda vocal.

2.
Hematol., Transfus. Cell Ther. (Impr.) ; 45(4): 428-434, Oct.-Dec. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1528638

ABSTRACT

ABSTRACT Introduction: In Brazil, the blood donor screening for hepatitis B virus (HBV) includes laboratory testing for serological (HBsAg and Anti-HBc) and molecular (HBV DNA) markers. This study aims to correlate serology reactive results with HBV DNA detection among blood donors with at least one HBV infection marker detected in a blood bank in northern Brazil. Method: A retrospective search for HBV reactive blood donor data from January 2017 to December 2019 was performed. Serological screening was performed by chemiluminescent microparticle immunoassays Architect HBsAg and Architect Anti-HBc, whereas molecular screening was performed by the HBV nucleic acid test (HBV NAT). Main results: A total of 556 HBsAg reactive results were detected, between positive (47.66%) and inconclusive (52.34%). A total of 3,658 Anti-HBc reactive results were detected, between positive (83.71%) and inconclusive (16.29%). None of the inconclusive results were associated with HBV DNA detection. The HBV DNA detection rates were 47.55% among HBsAg positive samples and 4.08% among Anti-HBc positive samples. The signal-to-cutoff (S/CO) ratio median of HBV NAT positive samples was superior in comparison to HBV NAT negative samples (p < 0.0001). The thresholds found to optimize sensitivity and specificity were 404.15 for Architect HBsAg and 7.77 for Architect Anti-HBc. Three blood donors were in the window period and 1 occult HBV infection case was detected. Conclusion: High S/CO ratios were more predictive of HBV DNA detection. However, a number of HBV NAT positive samples gave low values, while some HBV NAT negative samples showed high values, reaffirming the significance of molecular testing to enhance transfusion safety.

3.
Rev. argent. microbiol ; 55(3): 3-3, Oct. 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1529618

ABSTRACT

Abstract The rocketing number of COVID-19 cases highlighted the critical role that diagnostic tests play in medical and public health decision-making to contain and mitigate the SARS-CoV-2 pandemic. This study reports the evaluation and implementation of different tests for the molecular detection of SARS-CoV-2 in the central region of Argentina. We evaluated 3 real time RT-PCR kits (GeneFinder COVID-19 Plus RealAmp Kit, DisCoVery SARS-CoV-2 RT-PCR Detection Kit and WGene SARS-CoV-2 RT Detection), 2 nucleic acid extraction methods [MagaBio plus Virus DNA/RNA Purification Kit II (BioFlux), 35-min vs. 9-min, a pre-analytical reagent (FlashPrep®) and 2 isothermal amplification tests (Neokit Plus and ELA CHEMSTRIP®). The order according to the best performance of the 3 real-time RT-PCR kits evaluated was: DisCoVery > GeneFinderTM> WGene. The 2 RNA extraction methods showed similar good results: MagaBio plus Virus RNA Purification Kit II (BioFlux) 9-min was selected due to its faster performance. FlashPrep® reagent showed excellent results to perform direct RNA detection. Isothermal amplification assays showed acceptable sensitivity and specificity values (>80%), except in samples with Ct> 30. Our data show optimal real time RT-PCR kits and alternative molecular methods for SARS-CoV-2 diagnostic. These alternative assays proved to be aceptable.


Resumen La explosión de casos de COVID-19 resaltó el papel fundamental que desempeñan las pruebas de diagnóstico en la toma de decisiones médicas y de salud pública para contener y mitigar la pandemia de SARS-CoV-2. Este estudio reporta la evaluación y la implementación de diferentes test para la detección molecular de SARS-CoV-2 en la región central de Argentina. Evaluamos tres kits de RT-PCR en tiempo real (GeneFinder COVID-19 Plus RealAmp Kit, DisCoVery SARS-CoV-2 RT-PCR Detection Kit y WGene SARS-CoV-2 RT Detection), dos métodos de extracción de ácidos nucleicos (MagaBio plus Virus DNA/RNA Purification Kit II [BioFlux, 35-min vs. 9-min), un reactivo pre-analítico (FlashPrep®) y dos test de amplificación isotérmica (Neokit Plus and ELA CHEMSTRIP®). El orden de rendimiento de los tres kits de RT-PCR en tiempo real evaluados fue el siguiente: DisCoVery GeneFinder™ WGene. Los dos métodos de extracción de RNA mostraron buenos y similares resultados; se seleccionó MagaBio plus Virus RNA Purification Kit II (BioFlux) 9-min debido a su rápido tiempo de procesamiento. El reactivo FlashPrep® mostró excelentes resultados para realizar detección directa de RNA. Los ensayos de amplificación isotérmica mostraron valores de sensibilidad y de especificidad aceptables (80%), excepto en muestras con Ct 30. Nuestros resultados muestran kits de RT-PCR en tiempo real óptimos, como así también métodos moleculares alternativos para el diagnóstico de SARS-CoV-2 que resultan aceptables para su uso en contextos adversos, de descentralización y en diferentes escenarios epidemiológicos, para la detección rápida y precisa del SARS-CoV-2.

4.
Article | IMSEAR | ID: sea-223565

ABSTRACT

Background & objectives: Lysosomal storage disorders (LSDs) are genetic metabolic disorders which result from deficiency of lysosomal enzymes or defects in other lysosomal components. Molecular genetic testing of LSDs is required for diagnostic confirmation when lysosomal enzyme assays are not available or not feasible to perform, and for the identification of the disease causing genetic variants. The aim of this study was to develop a cost-effective, readily customizable and scalable molecular genetic testing strategy for LSDs. Methods: A testing method was designed based on the in-house creation of selective amplicons through long range PCR amplification for targeted capture and enrichment of different LSD genes of interest, followed by next generation sequencing of pooled samples. Results: In the first phase of the study, standardization and validation of the study protocol were done using 28 samples of affected probands and/or carrier parents (group A) with previously identified variants in seven genes, and in the second phase of the study, 30 samples of enzymatically confirmed or biopsy-proven patients with LSDs and/or their carrier parents who had not undergone any prior mutation analysis (group B) were tested and the sequence variants identified in them through the study method were validated by targeted Sanger sequencing. Interpretation & conclusions: This testing approach was found to be reliable, easily customizable and cost-effective for the molecular genetic evaluation of LSDs. The same strategy may be applicable, especially in resource poor settings, for developing cost-effective multigene panel tests for other conditions with genetic heterogeneity.

5.
Article | IMSEAR | ID: sea-221862

ABSTRACT

Background: Tuberculosis (TB) caused by Mycobacterium tuberculosis (Mtb) is still a major public health concern around the world. Prompt detection of active tuberculosis cases helps in timely therapeutic intervention and reduces community transmission. Despite limited sensitivity, conventional microscopy is still used to diagnose pulmonary tuberculosis in high-burden nations such as India. This study, therefore, was aimed at assessing the diagnostic performance of microscopy by Ziehl Neelsen (ZN) and auramine (AO) staining in the diagnosis of pulmonary tuberculosis. Materials and methods: A prospective comparative study was done on the sputum samples of 2,395 adult patients from November 2018 to May 2020 suspected of having pulmonary tuberculosis visiting the Designated Microscopic Centre of SGT Medical College, Budhera, Gurugram. Each sample was subjected to ZN staining, and AO staining as per NTEP guidelines. Results: Out of the 2,395 samples studied, 161 (6.76%) and 224 (9.35%) were positive by ZN and AO staining methods respectively. Pauci-bacillary cases detected by AO were more than ZN staining. There were 63 more sputum samples detected by AO staining which were missed by ZN microscopy. Conclusion: When compared to conventional ZN staining, the auramine staining technique is more sensitive and takes less time to diagnose pulmonary tuberculosis

6.
Article | IMSEAR | ID: sea-217974

ABSTRACT

Background: Malaria is a major health issue in tropical and subtropical areas. Out of all subtypes, Plasmodium falciparum (Pf) is the most dangerous form accounting for high mortality and morbidity. It is transmitted by infected female anopheles mosquitoes and infected blood transfusions. Aims and Objectives: The aim of the study is to establish correct diagnosis by direct microscopy, Immunochromatographic test (ICT), and molecular studies. Materials and Methods: This prospective study was conducted in the PG Department of Microbiology, SCB Medical College, Cuttack. Thick blood smears were drawn and then stained with Leishman’s stain to visualize falciparum rings. DNA was extracted from infected blood samples by phenol chloroform method with some modification as described by Sambrook and Russel for molecular analysis. Results: In the present study, 150 cases of malaria were analyzed. The male: female ratio was 1.7:1 and age ranged from 0 to 56 years. The Plasmodium vivax positivity was compared with thin smear to 21 (84%) in ICT, 100% both polymerase chain reaction (PCR) and loop mediated isothermal amplification assay (LAMP) assays followed by the Pf positivity as 76 (92.7%) in ICT, 82 (100%) both PCR and LAMP assays, respectively. The results obtained were statistically significant with P < 0.001. The PCR and LAMP showed 100% response to specificity and positive predictive value. Conclusion: The present study established the role of molecular tests such as PCR and LAMP are highly specific for diagnosis of Plasmodium species whereas they are more or less similar in sensitivity as compared to other diagnostic methods such as ICT and microscopy.

7.
Article | IMSEAR | ID: sea-223115

ABSTRACT

The neglected tropical disease mycetoma can become extremely devastating, and can be caused both by fungi and bacteria; these are popularly known as eumycetoma and actinomycetoma respectively. The classical triad of the disease is subcutaneous swelling, multiple discharging sinuses and the presence of macroscopic granules. The present study aims to highlight the existing diagnostic modalities and the need to incorporate newer and more advanced laboratory techniques like pan fungal/pan bacterial 16S rRNA gene polymerase chain reaction (PCR) and sequencing, Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS), rolling circle amplification (RCA), loop-mediated isothermal amplification (LAMP) and recombinase polymerase amplification (RPA). It is important for the medical team to be aware of the various diagnostic options (both existing and future), so that diagnosis of such a debilitating disease is never missed, both by clinicians and microbiologists/pathologists. The newer diagnostic methods discussed in this article will help in rapid, accurate diagnosis thus facilitating early treatment initiation, and decreasing the overall morbidity of the disease. In the Indian context, newer technologies need to be made available more widely. Making clinicians aware and promoting research and development in mycetoma diagnostics is the need of the hour.

8.
J Vector Borne Dis ; 2023 Jan; 60(1): 49-56
Article | IMSEAR | ID: sea-216916

ABSTRACT

Background & objectives: Timely intervention is needed to minimize the economic losses of vector-borne bovine anaplasmosis which can be possible by the isothermal amplification assay. Methods: Anaplasma marginale in the cattle of south Gujarat, India was detected in the PCR and LAMP by amplifying the fragment of msp5 gene. The PCR product was digested with EcoRI, and sequenced to confirm its pathogen specific detection. Results: Species specific PCR observed a band of 457 bp of msp5 DNA following 1% agarose gel electrophoresis. Positive LAMP reaction turned into yellow colour while negative sample depicted original pink colour. A detection limit of PCR and LAMP was up to 10-6 and 10-8 of the original genomic DNA of A. marginale, respectively. A single cut site of EcoRI was observed in the PCR product. Current msp5 DNA sequences of A. marginale (MW538962 and MW538961) showed 100% homology with the published sequences. Monophyletic lineage type relationship was observed with high bootstrap proportion among the msp5 DNA sequences of A. marginale in the phylogram. Prevalence rate of A. marginale was significantly higher (p<0.05) in the PCR [43/280 (15.36%)] and LAMP [62/280 (22.14%)] than the microscopic technique [17/280 (6.07%)]. Diagnostic sensitivity, specificity, positive and negative predictive values at 95% CI for LAMP assay with respect to PCR were 93.02%, 90.72%, 64.52% and 98.62%, respectively. Interpretation & conclusion: Thus LAMP can be a practical alternative to the PCR for the diagnosis of A. marginale infection in the cattle even in field condition

9.
Clinical Medicine of China ; (12): 53-56, 2023.
Article in Chinese | WPRIM | ID: wpr-992464

ABSTRACT

Objective:To investigate the clinical and genetic characteristics of Prader-Willi syndrome (PWS).Methods:The clinical data and genetic characteristics of 2 children with PWS diagnosed in Hebei Provincial People's Hospital were retrospectively analyzed, and the relevant literature was reviewed.Results:Case 1, male, aged 6 years and 3 months, was presented to the hospital because of short stature, mild mental retardation, dysarthria, scoliosis, cryptorchidism, micropenis, long skull, narrow face, almond eyes, small mouth, thin upper lip, downward corners of the mouth, fair skin. He had hypotonia and feeding difficulties in infancy, and gradually became hyperappetitive. Bilateral cryptorchidism surgery was performed at 1.5 years old, but the effect was not good. Case 2, male, aged 4 years, presented to the hospital mainly due to obesity, hyperappetite, excessive weight gain, backward language and cognitive function, dysarthria, and scoliosis.The infant had feeding difficulties in the early stage, and bilateral cryptorchidism surgery at the age of 2 was not effective.Methylation specific polymerase chain reaction and methylation specific multilink probe amplification were used to detect the loss of the parent fragment in the key region (15q11-13) of PWS, which confirmed Prader-Willi syndrome.Conclusion:PWS is a rare hereditary disease with complex and diverse clinical manifestations and different characteristics in different age groups. It is highly susceptible to unexplained hypotonia and feeding difficulties in infancy. Children with short stature and obesity should be alert to the disease, which can be clearly diagnosed by molecular genetic techniques.

10.
Journal of Pharmaceutical Analysis ; (6): 223-238, 2023.
Article in Chinese | WPRIM | ID: wpr-991138

ABSTRACT

Ensuring food safety is paramount worldwide.Developing effective detection methods to ensure food safety can be challenging owing to trace hazards,long detection time,and resource-poor sites,in addition to the matrix effects of food.Personal glucose meter(PGM),a classic point-of-care testing device,possesses unique application advantages,demonstrating promise in food safety.Currently,many studies have used PGM-based biosensors and signal amplification technologies to achieve sensitive and specific detection of food hazards.Signal amplification technologies have the potential to greatly improve the analytical performance and integration of PGMs with biosensors,which is crucial for solving the challenges associated with the use of PGMs for food safety analysis.This review introduces the basic detection principle of a PGM-based sensing strategy,which consists of three key factors:target recog-nition,signal transduction,and signal output.Representative studies of existing PGM-based sensing strategies combined with various signal amplification technologies(nanomaterial-loaded multienzyme labeling,nucleic acid reaction,DNAzyme catalysis,responsive nanomaterial encapsulation,and others)in the field of food safety detection are reviewed.Future perspectives and potential opportunities and challenges associated with PGMs in the field of food safety are discussed.Despite the need for complex sample preparation and the lack of standardization in the field,using PGMs in combination with signal amplification technology shows promise as a rapid and cost-effective method for food safety hazard analysis.

11.
China Tropical Medicine ; (12): 686-2023.
Article in Chinese | WPRIM | ID: wpr-979788

ABSTRACT

@#Abstract: Objective To establish a sensitive and specific nucleic acid detection method for Schistosoma japonicum based on loop-mediated isothermal amplification (LAMP) and clustered regularly interspaced short palindromic repeats (CRISPR) technology. Methods The LAMP primers, gRNA and ssDNA probe that target Schistosoma japonicum SjR2 genes were designed according to the principles of LAMP and CRISPR. The LAMP-CRISPR reaction system was established and optimized. The sensitivity and specificity of the method were evaluated against the ten-fold serial dilutions of plasmid containing SjR2 target sequences, as well as genomic DNA at different stages of Schistosoma japonicum and other parasites, including Fasciola hepatica, Schistosoma mansoni, Taenia saginata, Clonorchis sinensis, Ascaris lumbricoides, Necator americanus, Paragonimus westermani, and Echinococcus granulosus. Additionally, 15 schistosome-infected snail and 30 uninfected samples were tested by LAMP-CRISPR and LAMP methods, respectively, to evaluate the potential of this method for screening for infected snails. Results The developed LAMP-CRISPR method was able to specifically amplify and detect the SjR2 gene of S. japonicum. The optimal reaction temperature was 37 ℃, and the optimal reaction concentrations were both 40 nmol/L for gRNA and Cas12a protein. No cross-reaction was observed with genomic DNA from other parasites such as F. hepatica. The detection limit of the method was 10 copies/μL when testing 10-fold dilutions of recombinant plasmids as a template. Furthermore, the LAMP-CRISPR method was able to accurately detect genomic DNA from S. japonicum at various stages of development, including eggs, cercariae, schistosomula, juvenile worms, and adult worms. The results of testing 45 snail samples showed no significant difference between the LAMP-CRISPR and LAMP methods for detecting infected snails (χ2=0.05, P>0.05). The sensitivity and specificity of the LAMP-CRISPR method were 100.00% (15/15) and 96.67% (29/30), respectively, compared to the gold standard, while the sensitivity and specificity of the LAMP method were 100.00% (15/15) and 93.33% (28/30), respectively. Conclusions This established LAMP-CRISPR detection method presented good sensitivity, specificity and reliability, making it a promising tool for rapid detection and risk monitoring of S. japonicum.

12.
China Tropical Medicine ; (12): 251-2023.
Article in Chinese | WPRIM | ID: wpr-979625

ABSTRACT

@#Abstract: Objective To evaluate the value and significance of rifampicin-resistant real-time fluorescence quantitative nucleic acid amplification detection technology (GeneXpert MTB/RIF) in the diagnosis of pulmonary tuberculosis.   Methods The clinical data of 228 patients with suspected pulmonary tuberculosis, who admitted to Hebei Chest Hospital from January 2018 to December 2019, were analyzed retrospectively. The sputum was collected for GeneXpert MTB/RIF, sandwich cup liquid-based bacterial acid-fast staining smear microscopy (referred to as “sandwich cup method”) and Loop-Mediated isothermal amplification (referred to as “LAMP method”) and the results were statistically analyzed by SPSS 17.0 software. Results Among the 228 patients with suspected cases, 200 cases were clinically diagnosed as pulmonary tuberculosis and 28 were non-tuberculosis. The positive detection rate of GeneXpert MTB/RIF (81.0%, 162/200) was significantly higher than that of sandwich cup method (62.5%, 125/200) and LAMP method (72.5%,145/200) (χ2=16.885, 4.049, P<0.05). Taking clinical diagnosis as gold standard, the sensitivity of GeneXpert MTB/RIF (80.00%,160/200) was significantly higher than that of sandwich cup method (60.00%, 120/200) and LAMP method (70.50%, 141/200) (χ2=19.048, 4.846, P<0.05). The diagnostic consistency of GeneXpert MTB/RIF (K=0.73) was higher than that of sandwich cup method (K=0.39) and LAMP method (K=0.56). Conclusions The GeneXpert MTB/RIF detection method is rapid and simple, and can diagnose pulmonary tuberculosis rapidly and simultaneously detect rifampicin resistance of Mycobacterium tuberculosis with high sensitivity. It has high clinical value for early diagnosis of pulmonary tuberculosis and guidance of treatment in general and specialized hospitals.

13.
China Tropical Medicine ; (12): 240-2023.
Article in Chinese | WPRIM | ID: wpr-979623

ABSTRACT

@#Abstract: Objective To analyze the value and influencing factors of cross-primer isothermal amplification technology(CPA) in clinical screening and diagnosis of tuberculosis (TB). Methods We collected 543 inpatients in the Second Affiliated Hospital of Hainan Medical College from January 1, 2018 to December 31, 2021, including 179 patients with tuberculosis, 187 patients with pneumonia and 177 patients with other diseases. The patients' sputum, alveolar lavage fluid, pleural effusion and midstream urine were detected by CPA, smear microscopy, culture method and gene detection. The value of CPA detection in the diagnosis of tuberculosis and its influencing factors were evaluated. Statistical analysis was performed using SPSS 26.0. Results The total positive rate of CPA was 14.4% (78/543), and the positive rate of sputum samples accounted for 29.1% (39/134). Among the 78 cases of CPA positive patients, the tuberculosis group accounted for 69.2% (54/78), followed by pneumonia group 21.8% (17/78), and other diseases group accounted for 9.0% (7/78). Taking CPA test as the reference method, the "sensitivity" of smear microscopy was lower than that of genetic testing and culture, while the "specificity" was higher than that of culture and gene testing, and the "missed diagnosis rate" of smear microscopy was higher than that of genetic testing and culture. CPA test positive was related to gender, ESR and pneumonia. There is a good agreement between CPA test and culture method and gene test (Kappa>0.9), and a moderate agreement between CPA test and smear microscopy (Kappa=0.616). Conclusions Sputum specimen is the best choice for CPA detection, while the value of pleural effusion detection is relatively limited. Sputum, alveolar lavage fluid and midcourse urine can be used as clinical specimens for screening and diagnosis of "tuberculosis group and other disease group", while sputum can be used for screening and diagnosis of "tuberculosis group and pneumonia group". Gender, ESR and pneumonia are the influencing factors of CPA positive patients. Therefore, CPA testing is worthy of clinical promotion, but more clinical research data are needed.

14.
Chinese Journal of Hematology ; (12): 141-147, 2023.
Article in Chinese | WPRIM | ID: wpr-969690

ABSTRACT

Objective: To investigate the causative factors of renal function in newly diagnosed multiple myeloma (MM) patients with renal inadequacy. Methods: 181 MM patients with renal impairment from August 2007 to October 2021 at Peking Union Medical College Hospital were recruited, whose baseline chronic kidney disease (CKD) stage was 3-5. Statistical analysis was performed based on laboratory tests, treatment regimens, hematological responses, and survival among various renal function efficacy groups. A logistic regression model was employed in multivariate analysis. Results: A total of 181 patients were recruited, and 277 patients with CKD stages 1-2 were chosen as controls. The majority choose the BCD and VRD regimens. The progression-free survival (PFS) (14.0 months vs 24.8 months, P<0.001) and overall survival (OS) (49.2 months vs 79.7 months, P<0.001) of patients with renal impairment was considerably shorter. Hypercalcemia (P=0.013, OR=5.654) , 1q21 amplification (P=0.018, OR=2.876) , and hematological response over a partial response (P=0.001, OR=4.999) were independent predictive factors for renal function response. After treatment, those with improvement in renal function had a longer PFS than those without (15.6 months vs 10.2 months, P=0.074) , but there was no disparity in OS (56.5 months vs 47.3 months, P=0.665) . Conclusion: Hypercalcemia, 1q21 amplification, and hematologic response were independent predictors of the response of renal function in NDMM patients with renal impairment. MM patients with CKD 3-5 at baseline still have worse survival. Improvement in renal function after treatment is attributed to the improvement in PFS.


Subject(s)
Humans , Multiple Myeloma/drug therapy , Bortezomib/therapeutic use , Hypercalcemia , Prognosis , Chromosome Aberrations , Kidney/physiology , Renal Insufficiency, Chronic , Retrospective Studies , Antineoplastic Combined Chemotherapy Protocols
15.
Chinese Journal of Schistosomiasis Control ; (6): 38-43, 2023.
Article in Chinese | WPRIM | ID: wpr-965526

ABSTRACT

Objective To establish a fluorescent assay for rapid detection of Plasmodium falciparum based on recombinaseaided amplification (RAA) and CRISPR-Cas12a system,and to preliminarily evaluate the diagnostic efficiency of this system.. Methods The 18S ribosomal RNA (rRNA) gene of P. falciparum was selected as the target sequence, and three pairs of RAA primers and CRISPR-derived RNA (crRNA) were designed and synthesized. The optimal combination of RAA primers and crRNA was screened and the reaction conditions of the system were optimized to create a fluorescent RAA/CRISPR-Cas12a system. The plasmid containing 18S rRNA gene of the P. falciparum strain 3D7 was generated, and diluted into concentrations of 1 000, 100, 10, 1 copy/μL for the fluorescent RAA/CRISPR-Cas12a assay, and its sensitivity was evaluated. The genomic DNA from P. vivax, P. malariae, P. ovum, hepatitis B virus, human immunodeficiency virus and Treponema pallidum was employed as templates for the fluorescent RAA/CRISPR-Cas12a assay, and its specificity was evaluated. Fifty malaria clinical samples were subjected to the fluorescent RAA/CRISPR-Cas12a assay and nested PCR assay, and the consistency between two assays was compared. In addition, P. falciparum strain 3D7 was cultured in vitro. Then, the culture was diluted into blood samples with parasite densities of 1 000, 500, 200, 50, 10 parasites/μL with healthy volunteers’ O-positive red blood cells for the RAA/CRISPR-Cas12a assay, and the detection efficiency was tested. Results The Pf-F3/Pf-R3/crRNA2 combination, 2.5 μL as the addition amount of B buffer, 40 min as the RAA reaction time, 37 °C as the reaction temperature of the CRISPR-Cas12a system were employed to establish the fluorescent RAA/CRISPR-Cas12a system. Such a system was effective to detect the plasmid containing 18S rRNA gene of the P. falciparum strain 3D7 at a concentration of 1 copy/μL, and presented fluorescent signals for detection of P. falciparum, but failed to detect P. ovum, P. malariae, P. vivax, T. pallidum, hepatitis B virus or human immunodeficiency virus. The fluorescent RAA/CRISPR-Cas12a system and nested PCR assay showed completely consistent results for detection of 50 malaria clinical samples (kappa = 1.0, P < 0.001). Following 6-day in vitro culture of the P. falciparum strain 3D7, 10 mL cultures were generated and the fluorescent RAA/CRISPR-Cas12a system showed the minimal detection limit of 50 parasites/μL. Conclusion The fluorescent RAA/CRISPR-Cas12a system is rapid, sensitive and specific for detection of P. falciparum, which shows promising value for rapid detection and risk monitoring of P. falciparum.

16.
Journal of Experimental Hematology ; (6): 553-561, 2023.
Article in Chinese | WPRIM | ID: wpr-982094

ABSTRACT

OBJECTIVE@#To explore the similarities and variations of biological phenotype and cytotoxicity of human umbilical cord blood natural killer cells (hUC- NK) after human umbilical cord blood-derived mononuclear cells (hUC-MNC) activated and expanded by two in vitro high-efficient strategies.@*METHODS@#Umbilical cord blood mononuclear cells (MNC) from healthy donor were enriched by Ficoll-based density gradient centrifugation. Then, the phenotype, subpopulations, cell viability and cytotoxicity of NK cells derived from Miltenyi medium (denoted as M-NK) and X-VIVO 15 (denoted as X-NK) were compared using a "3IL" strategy.@*RESULTS@#After a 14-day's culture, the contents of CD3-CD56+ NK cells were elevated from 4.25%±0.04% (d 0) to 71%±0.18% (M-NK) and 75.2%±1.1% (X-NK) respectively. Compared with X-NK group, the proportion of CD3+CD4+ T cells and CD3+CD56+ NKT cells in M-NK group decreased significantly. The percentages of CD16+, NKG2D+, NKp44+, CD25+ NK cells in X-NK group was higher than those in the M-NK group, while the total number of expanded NK cells in X-NK group was half of that in M-NK group. There were no significant differences between X-NK and M-NK groups in cell proliferation and cell cycle, except for the lower percentage of Annexin V+ apoptotic cells in M-NK group. Compared with X-NK group, the proportion of CD107a+ NK cells in M-NK group were higher under the same effector-target ratio (E∶T) (P<0.05).@*CONCLUSION@#The two strategies were adequate for high-efficient generation of NK cells with high level of activation in vitro, however, there are differences in biological phenotypes and tumor cytotoxicity.


Subject(s)
Humans , Fetal Blood , Killer Cells, Natural , T-Lymphocytes , Leukocytes, Mononuclear/metabolism , Cell Proliferation , CD56 Antigen/metabolism
17.
Ginecol. obstet. Méx ; 91(2): 100-108, ene. 2023. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1448320

ABSTRACT

Resumen OBJETIVO: Analizar los posibles factores asociados con las fallas en la amplificación, los desenlaces de la euploidia y clínicos entre los embriones con repetición de la biopsia y los de una sola (grupo control). MATERIALES Y MÉTODOS: Estudio retrospectivo y multicéntrico de análisis de biopsias de blastocistos practicadas en 22 centros de reproducción asistida (noviembre 2017 a febrero 2022). Se analizaron 4,106 blastocistos procedentes de 1,007 ciclos de ICSI con prueba genética para aneuplidias previa a la implantación. En los blastocistos reportados con falla en la amplificación se analizó el Centro donde se practicó la biopsia, el día en que ésta se tomó, la calidad embrionaria y la incidencia de complicaciones durante el procedimiento. Los resultados se compararon con la prueba genética para aneuploidias previa a la implantación y los desenlaces clínicos entre los embriones con repetición de la biopsia y el grupo control. RESULTADOS: En el 96.0% (3,942) de los embriones se obtuvo resultado y en el 4.0% (n = 164) se reportó falla en la amplificación. La biopsia se repitió en las 99 fallas en la amplificación y se obtuvo resultado en el 83.8% de los casos. Las tasas de euploidia fueron similares entre embriones con repetición de la biopsia y los controles (34.9 en comparación con 39.7%; p > 0.05). El Centro fue el único factor que mostró diferencias en las tasas de falla en la amplificación (p < 0.05). No se observaron diferencias en el día de la biopsia o la calidad embrionaria. Las tasas de embarazo (51.0 en comparación con 58.3%), implantación (63.9 en comparación con 61.5%) y aborto (16.9 en comparación con 28.6%) fueron similares entre embriones con una sola biopsia o repetición de ésta, respectivamente. CONCLUSIONES: El Centro fue el principal factor que influyó en las fallas en la amplificación. Las tasas de euploidia y los desenlaces clínicos no difirieron entre el grupo control y los embriones con repetición de la biopsia; por consiguiente, se recomienda repetir la biopsia en los embriones con falla en la amplificación.


Abstract OBJECTIVE: To analyze possible factors associated with amplification failures, euploidy and clinical outcomes between repeat and single biopsy embryos (control group). MATERIALS AND METHODS: Retrospective multicenter study involving 4,106 blastocysts from 1,007 ICSI cycles with preimplantation genetic testing for aneuploidy performed by next generation sequencing. In case of DNA amplification failure, the IVF center where biopsies were performed, the day of biopsy, the embryo quality and the incidence of complications during biopsy were analyzed. Preimplantation genetic testing for aneuploidy results and clinical outcomes were compared between re-biopsied embryos and the control group. RESULTS: Of the 4,106 blastocysts included in this study, 96.0% (3,942) obtained a result while 4.0% (164) had an amplification failure. Ninety-nine embryos with amplification failure were re-biopsied and 83.8% resulted in an informative diagnosis. Euploidy rates were equivalent between re-biopsied and control blastocysts (34.9% vs 39.7%, P>0.05). The only factor significantly affecting the amplification failure rates was the IVF center. No differences were observed between biopsy days or embryo quality. Pregnancy (51.0% vs 58.3%), implantation (63.9% vs 61.5%) and miscarriage rates (16.9% vs 28.6%) were similar between single and repeat biopsied embryos, respectively. CONCLUSIONS: The centre was the main factor influencing amplification failures. Euploidy rates and clinical outcomes did not differ between the control group and repeat biopsied embryos; therefore, repeat biopsy is recommended for embryos with amplification failure.

18.
China Tropical Medicine ; (12): 870-2023.
Article in Chinese | WPRIM | ID: wpr-1005156

ABSTRACT

@#Abstract: Objective To establish a method for detecting sdaB virulence gene of Streptococcus pyogenes with loop mediated isothermal amplification (LAMP). Methods According to the conserved sequence of Streptococcus pyogenes sdaB gene published in GenBank (GenBank: 69901515), LAMP primers were designed with Primer Explorer V5.0 software. Main components of LAMP reaction system were optimized including of fluorescent dye, MgSO4, betaine, deoxyribonucleosidetriphosphate (dNTP), and Bst DNA polymerase, with the concentration of MgSO4 from 0 mmol/L to 12 mmol/L, betaine from 0 mol/L to 2.4 mol/L, dNTP from 0.2 µmol/L to 2 µmol/L, forward inner primer (FIP) and backward inner primer (BIP) from 0.2 µmol/L to 2 µmol/L respetively, forward outer primer (F3) and backward outer primer (B3) from 0.2 µmol/L to 0.4 µmol/L, Bst DNA polymerase from 0.16 U/µL to 0.96 U/µL, fluorescent dye from 0.2 µmol/L to 2 µmol/L. With the optimized system, the methodological specificity and the minimum detection limit were evaluated on the ABI7500 real-time fluorescent quantitative PCR analyzer, and 13 standard strains including Group A Streptococcus, Group B Streptococcus, Group C Streptococcus, Group G Streptococcus, Streptococcus pneumoniae, Streptococcus viridis, Enterococcus faecalis, Enterococcus faecium, Neisseria gonorrhoeae, Lactobacillus acidophilus, Escherichia coli, Klebsiella pneumoniae and Pseudomonas aeruginosa were detected. Finally, 103 clinical samples were tested. Results The optimized reaction system contained 25 µL reaction mixture, including 0.8 µL of 25 µmol/L fluorescent dye, 1 µL of 100 mmol/L MgSO4, 6 µL of 5 mol/L betaine, 1.4 µL of 25 mmol/L dNTP, 2 µL of 20 µmol/L FIP and BIP, 0.5 µL of 20 µmol/L F3 and B3, 1 µL of 8 U/µL Bst DNA polymerase, and 2 µL of template. After adding deionized water, the mixture was incubated at 63°C for 45 min to complete the reaction. The limit of detection (LOD) was 500 pg/µL. All 12 non-S. pyogenes strains tested were negative. Compared with the culture method, the clinical sensitivity and specificity were 100.0% (16/16) and 96.6% (84/87), respectively, for 103 clinical samples. Conclusions This LAMP assay is reliable for the detection of Streptococcus pyogenes in clinic and is suitable for field detection with good specificity and sensitivity, as well as simply operation.

19.
China Tropical Medicine ; (12): 846-2023.
Article in Chinese | WPRIM | ID: wpr-1005152

ABSTRACT

@#Abstract: Objective To compare the diagnostic efficacy of the upgraded version of the GeneXpert automated fluorescent quantitative PCR system (GeneXpert MTB/RIF Ultra, GeneXpert Ultra) and the original version of the GeneXpert system (GeneXpert MTB/RIF, Xpert), real-time fluorescent quantitative nucleic acid detection (FQ-PCR), real-time fluorescent thermostatic amplification of Mycobacterium tuberculosis RNA (SAT-RNA), real-time fluorescent thermostatic amplification detection of DNA (thermostatic amplification method) and traditional BACTEC MGIT 960 liquid culture (culture method) for special specimens of tuberculosis, in order to analyze its application value in clinical detection. Methods Using prospective research methods, a total of 170 special specimens (including 47 pleural and ascites effusion samples, and 34 24-hour urinary sediment specimens, 49 tissue specimens and 40 fester specimens) were collected i'an Chest Hospital from January to September 2021. GeneXpert Ultra, Xpert, FQ-PCR, SAT-RNA, isothermal amplification, and traditional culture were used for detection. Clinical diagnosis was used as the standard, and sensitivity, specificity, positive predictive value, negative predictive value, coincidence rate, and Kappa value were compared among the methods. Results The sensitivities of GeneXpert Ultra, Xpert, FQ-PCR, SAT-RNA, isothermal amplification, and traditional culture were 65.18% (73/112), 49.11% (55/112), 37.50% (42/112), 19.64% (22/112), 8.04% (9/112), and 22.32% (25/112), respectively. The sensitivity of GeneXpert Ultra was higher than that of the other five methods, and the differences were statistically significant (χ2=66.25, 42.10, 28.89, 13.09, 4.92, 15.18, all P<0.05). GeneXpert Ultra result analysis showed that: 5.48%(4/73) cases had trace, that is, trace Mycobacterium tuberculosis load, 79.45% (58/73) cases were extremely low, 10.96% (8/73) cases were low, 2.74% (2/73) were medium, , and 1.36% (1/73) were high load. In 4 trace samples, the Xpert detection was negative for all. Of the 73 GeneXpert Ultra positive reports, 63 were rifampicin-sensitive, 6 were rifampicin-resistant, and 4 were rifampicin-resistant but of unclear resistance. Of the 55 Xpert positive reports, 45 were rifampicin-sensitive, 2 were rifampicin-resistant, and 8 were rifampicinresistant but of unclear resistance.. Conclusions The new generation of GeneXpert MTB/RIF Ultra has high sensitivity, specificity and drug resistance detection rate, and its advantage is even more apparent in the pathogenic diagnosis of special specimens of tuberculosis. It can be used as one of the preferred methods in samples with low bacterial load.

20.
Chinese Journal of Blood Transfusion ; (12): 587-590, 2023.
Article in Chinese | WPRIM | ID: wpr-1004789

ABSTRACT

【Objective】 To analyze the influencing factors of the repeat reactive (RR) rates of minipools implicated in minipool (MP) nucleic acid testing(NAT) in Xiamen Blood Center, in order to provide reference for NAT. 【Methods】 Samples of blood donors from January 1, 2019 to October 31, 2022 were collected in Xiamen Blood Center and tested by MP-NAT(pools of six). Statistical analysis and comparison of MP-NAT RR rates was performed among different years, testers, reagent batches, instrument combinations, CT values of MP-NAT reactive pools and sample backgrounds. 【Results】 A total of 234 715 blood samples were tested by MP-NAT, and 428 pools were reactive, in which 248 pools were individual-donor NAT reactive, with a MP-NAT RR rate of 57.9%. The difference of MP-NAT RR rates were not statistically significant among different years, testers, reagent batches, instrument combinations, and sample backgrounds (P> 0.05). The difference of MP-NAT RR rates among different CT values of MP-NAT reactive pools was statistically significant (χ2=69.587, P<0.05). Significantly abnormal RR rate accurred in two months in 2022, and returned to normal after timely handling. 【Conclusion】 The MP-NAT RR rates is one of the important indicators to monitor the quality of NAT. Once there is a significant change in the MP-NAT RR rates, comprehensive analysis and timely handling should be carried out to ensure the quality of blood detection.

SELECTION OF CITATIONS
SEARCH DETAIL